1310nm/28dB+1550nm/26dB SM OTDR Testing and OPM+10G OPM+OLS+VFL+Event Map+Optical Loss Tester+Multi-Fiber Testing+RJ45 Cable Test Fiber Tester Compatible with APC&UPC SC+FC+ST+LC-SS305T-2A1
- 🏅1310nm/28dB+1550nm/26dB: The SS305T-2A1 produced by SKYSHL is a very smart handheld OTDR fiber tester with a dual wavelength of 1310nm+1550nm, a maximum dynamic range of 28dB+26dB, and a maximum test distance of up to 80km. It is the best tool for fiber installation and maintenance. At the same time, the professional team provides 24-hour professional technical support, 3-year worry-free guarantee, and lifetime maintenance.
- 🏅12 AND 1 FUNCTIONS: SKYSHL SS305T-2A1 includes 12 functions: OTDR (1310nm/28dB+1550nm/26dB), event map, 10G OPM (1490nm+1577nm/-40~+10dBm), OUN status test (distance/loss/event/fiber connection/fiber break), OPM (OPM-800-1700nm/-50~+26dBm), VFL (10km test distance), OLS (1310nm+1550nm), optical loss tester, optical power loss test, power line test RJ45 network (RJ45 cable tracing, RJ45 cable sequence, RJ45 length test) and multi-fiber test, etc.
- 🏅EXTREME BLIND ZONE-EDZ(3.0m)+ADZ(8.0m): SS305T-2A1 1310nm and 1550nm SM OTDR adopts the most advanced optical technology and analysis algorithm to provide users with a very short event blind zone (SM is 3.0m) and attenuation blind zone (SM is 8.0m), thus providing the best solution for users to detect short-distance faults plan.
- 🏅AUTO OTDR MODE+EXPERT OTDR MODE+EVENT MAP FUNCTION: SKYSHL SS305T-2A1 1310nm and 1550nm optical time domain reflectometer provides a variety of intelligent test modes, so even unfamiliar users can become test experts. The event map function provided by SS305T-2A1 simplifies test events into graphics, providing great convenience for users to analyze problems.
- 🏅COMPATIBLE WITH APC&UPC SC+ST+FC+LC: SKYSHL SS305T-2A1 1310nm and 1550nm Single mode OTDR provides SC, FC adapter, 2*FC-FC/SM fiber optic patch cord and FC-SC, FC-ST, FC-LC, FC-FC flange , various types of fiber optic connectors can be connected through fiber optic jumpers and flanges.
Estimated shipping
Select a product to estimate shipping.SKYSHL 1310nm/28dB+1550nm/26dB SM Fiber OTDR Tester
An Optical Time Domain Reflectometer (OTDR) is an important instrument used by organizations to certify the performance of new fiber optics links and detect problems with existing fiber links.
With the rapid advancements in fiber optic technology, OTDR testing methods have become indispensable to building, certifying, maintaining and troubleshooting fiber optic systems.
SKYSHL provides a new Optical Time Domain Reflectometer(OTDR)--SS304T series. They are used to measure the fiber length and overall optical attenuation in a circuit. The analyzed data provides insight into the integrity of the fiber and any passive optical components (such as connectors, splices, splitters, and multiplexers) transmitted along the cable path.
SKYSHL 1310nm+1550nm 28dB+26dB SM Fiber OTDR Key Features:
1310nm+1550nm 28dB+26dB OTDR tester (maximum test distance: 80km/50mi).
The SS305T is very compact and very convenient to carry outdoors.
The 4.3-inch capacitive touch screen makes the operation more sensitive.
3.7V/4000mAh lithium battery, continuous use for 11-15 hours
12-in-1 function, integrating optical time domain reflectometer, event map, 10G PON split-wavelength optical power meter, end status verification, multi-core test, stable optical source, optical power meter, optical loss test, RJ45 network cable length, RJ45 line sequence test, RJ45 network cable search, fiber end detection, wireless charging and other functions.
One-button operation, automatic analysis and OTDR user interface tailored for different skill levels. Very short event dead zone (3.0m) and attenuation dead zone (8.0m).
2.5mm universal interface, compatible with APC&UPC SC+FC+ST+LC connectors.
Supports automatic OTDR, expert OTDR, event map, intelligent graphic analysis of fiber connections
Supports SOR file format.
Supports Chinese, English, German, French, Spanish, Italian, Russian, Spanish and Portuguese.
Smart OTDR
Automatic testing allows you to take full advantage of the full capabilities of OTDR - taking automation to a new level and allowing untrained technicians to become testing experts in a short time.
With just one click, the device automatically performs link identification, sets optimal parameters and starts data acquisition, integrating the results obtained for each link section and each network element, and immediately obtains accurate information for each link element and presents it to the user through the test curve.
At the same time, SKYSHL SS305T series OTDR has the most advanced optical technology, which can achieve extremely short event blind zone (SM typical value is 3.0m) and attenuation blind zone (SM typical value is 8.0m). This advanced optical technology enables the SS305T Series OTDR to detect faults on very short optical fibers.
SS305T-2A1(1310nm+1550nm 28dB+26dB) SM Fiber OTDR Key Parameters:
Model: SS305T-2A1.
Wavelength/dynamic range: Single mode 1310nm+1550nm/28dB+26dB (maximum test distance: 80km).
EDZ/ADZ: 3.0m/8.0m.
Data storage: 800,000 sets of curves (with 8GB micro SD/TF).
Display: 4.3-inch capacitive touch screen.
Battery: 3.7V/4000mAh lithium battery.
Dimensions: 180*110*43mm/0.5kg (including battery).
Optical power meter: 800nm~1700nm; -50~+26dBm.
Light source/optical loss test (OLS): 1310nm+1550nm.
VFL: 10km.
10G PON OPM: 1490nm & 1577nm (range: +10~-40dBm).
OTDR Test Curve and Event Type
A picture is worth a thousand words, and the OTDR picture (or "trace") takes a lot of words to describe all the information in it!
The slope of the fiber trace shows the attenuation coefficient of the fiber and is calibrated in dB/km by the OTDR. Connectors and splices are called "events" in OTDR jargon. Both should show a loss, but connectors and mechanical splices will also show a reflective peak. The height of that peak will indicate the amount of reflection at the event.
Reflective pulses can show you the resolution of the OTDR. You cannot see two events closer than is allowed by the pulse width. Generally longer pulse widths are used to be able to see farther along the cable plant and narrower pulses are used when high resolution is needed, although it limits the distance the OTDR can see.
Built-in Auto OTDR+Expert OTDR+10G PON OPM+OPM+OLS+VFL+Optical Loss Test+RJ45 Cable Test+Multi Test
SKYSHL SS305T-2A1 optical time domain reflectometer is a multifunctional optical measuring instrument, integrating optical time domain reflectometer (Auto OTDR/Expert OTDR-1310nm+1550nm/28dB+246dB), event map, 10G split-wavelength optical power meter (10G OPM-1490nm&1577nm/+10~-40dBm), end status verification, multi-core test, stable light source (OLS-1310nm+1550nm), optical power meter (OPM-800nm-1700nm/-50~+26db), optical loss test (OFLT-1310nm+1550nm), RJ45 network cable length, RJ45 line sequence test, RJ45 network cable search, fiber end detection, wireless charging and other functions. The 4.3-inch capacitive color touch screen and button dual design are simple to operate and have a friendly interface. It is a powerful assistant for optical cable construction and installation, project acceptance and on-site repair.
Event Map/Graphics Analysis Mode
The OTDR optical fiber test is simplified through the event map, and the representation accuracy of the network topology is optimized through intelligent algorithms, and all network components and fault locations are dynamically located and identified at the maximum resolution, thereby bringing a new experience to the optical fiber test engineer.
SS305T-2A1(1310nm+1550nm 28dB+26dB) SM Fiber OTDR Package List:
1*OTDR main unit + 1*SC&FC/UPC (for OTDR) connector + 2*2.5mm universal connector (for OPM&VFL) + 4*Flange Compatible with APC&UPC (1*FC-FC + 1*FC-SC + 1*FC-LC + 1*FC-ST) + 2*FC-FC Patch Cord + 1*User's Manual+1*USB cable+1* Charger + 1*Cotton swab stick (for cleaning the interface) + 1*Oxford backpack + 1*RJ45 Cable Locator + 1*RJ45 Remote Module + 8G Micro-SD/TF card (with electronic version of instructions, emulation software).
Quality Control and SKYSHL
SKYSHL has more than 10 years of experience in manufacturing optical fiber inspection equipment such as fusion splicers, OTDRs, and optical power meters. We have an excellent R&D team and after-sales team. We regard product quality as life, and strictly follow ISO9001 for production management. The entire production process is strictly controlled, and all products have undergone high temperature test, low temperature test, vibration test, charge and discharge test before leaving the factory.
At the same time, we continue to improve our work and have a team of professional after-sales on standby 24 hours a day to provide each customer with a full range of professional technical guidance.
We provide detailed product information and usage videos for all products, such as user manuals, test reports, calibration certification, operation videos, maintenance videos, etc., so that customers can start working immediately after they get the products.
We provide a free replacement for 3 years. When you encounter problems, we are the strongest backing for our customers.
Product details






Especificaciones
| Main Specification | |
|---|---|
| Dispositivos compatibles | Fiber optic connectors (SC, FC, ST, LC), Multi-fiber testing devices, RJ45 cable testing devices |
| Fabricantes | SKYSHL |
| Cuenta de unidad | 1 Cuenta |
| Medida de especificación | 1310&1550nm 28&26db | 5m-80km |
| Marca | SKYSHL |
| Número de artículos | 1 |
| Componentes incluidos | 1*SS305T-2A1 OTDR |
| Fuente de energía | 3.7v 4000mah Lithium Battery |
| Clasificación superior de temperatura | 80 °C |
| Color | azul |
| Peso del artículo | 0,8 kg |
| Technical Details | |
|---|---|
| Número de la parte | SS305T-2A1 |
| Modelo | SS305T-2A1 |
| Tipo de medida | Optical Time Domain Reflectometry |
| Máxima tensión de funcionamiento | 4.25 volts_of_direct_current |
| Style | |
|---|---|
| Nombre del estilo | SS305T-2A1(1310/1550nm 28/26dB) |
| Measurements | |
|---|---|
| Tema Dimensiones | 7.09 x 1.5 x 4.53 inches |
| Otros | |
|---|---|
| Tipo de producto | Network & Cable Testers |
| Tensión mínima de funcionamiento | 3 volts_of_direct_current |
| Etiquetas | |
|---|---|
| Etiquetas | |